logo
İyi fiyat  çevrimiçi

Ürün ayrıntıları

Evde > Ürünler >
Pil Yaşlanma Makinesi
>
30V 10A 20A Battery Pack Charging and Discharging Machine Battery Pack Aging Machine

30V 10A 20A Battery Pack Charging and Discharging Machine Battery Pack Aging Machine

Marka Adı: XWELL
Model Numarası: BCDS70-05-10
Adedi: 1 adet
fiyat: USD 2000/pcs
Paketleme Detayları: ahşap kutu
Ödeme Koşulları: T/T, Western Union, L/C
Detay Bilgisi
Menşe yeri:
Çin
Sertifika:
CE
Satış Sonrası Hizmet:
Tedarik edilen
tip:
Yarı otomatik
Güç Kaynağı:
AC220V 50Hz
Şarj Doğruluğu:
±(okumanın %0,2'si +aralığın %0,2'si)
Deşarj Aralığı:
50-10000mA
Deşarj Doğruluğu:
±(okumanın %0,2'si +aralığın %0,2'si)
Sabit Gerilim Kesme Akımı:
Minimum 50mA
Deşarj gücü:
≤700W
Muayene Süresi:
Gerçek Zamanlı Toplama<2S
Menşe yeri:
Çin
Yetenek temini:
Ayda 100 adet
Vurgulamak:

30V 20A battery aging machine

,

10A battery pack charging machine

,

battery pack discharging machine with warranty

Ürün Açıklaması

30V 10A 20A Battery Pack Charging and Discharging Machine Battery Pack Aging Machine


Product Description

The basic performance of the tester

 

1. Charging and discharging functions

It has the functions of constant current and voltage charging and constant current discharging, charging and discharging batteries and recording the capacity of batteries.

 

2. Charge-discharge interface

It fully meets the requirements of charging and discharging ports and charging and discharging ports of battery packages, namely, two wires (P + P-) and three wires (P + P - C-). At the same time, the electric tool battery (CH+P+P-) which can aging positive plate charging protection and negative plate discharging protection can be used.

 

3. Check Voltage Protection

By charging and discharging the batteries, it can be detected whether the charging protection and discharging protection of the batteries play a role.

Product Features
  • mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab. 
  • Support battery circle life testing, capacity testing, charging characteristic testing, discharging characteristic testing, charg retention capability testing, charge and discharge efficiency testing, over charge or over discharge rate affordability testing.

 
Product Specification
 

Technical Parameter

 
Input Power Supply

Measuring Range 7-70V

Accuracy ±(0.2% of reading +0.2% of range)

 
 
Current
 
 
 
 
 
 

Charging Range 50-5000mA
Charging Accuracy ±(0.2% of reading +0.2% of range)
Discharge Range 50-10000mA
Discharge Accuracy ±(0.2% of reading +0.2% of range)
Charge Constant Voltage Cut-off Current Minimum 50mA
Capacity Accuracy ±1%
Power Discharge Power ≤700W
Time Inspection Time Real-time Collection<2S

Timing Range 0-999h/step
Data Recording Interval ≥5S
Middle Machine Version 1:1 series
Number of Passages Per Cabinet 12 channels, four rows and three column

Charge
 

Charging Mode Constant Current and Constant Voltage Charging
Cut-off condition Voltage, Current, Relative Time, Overcharge Protection
Discharge Discharge mode Constant current discharge

Cut-off condition Voltage, Relative Time and Over-discharge Protection
Loop Cyclic measurement range 1-999 times

Single cycle step number 100
Voltage and Current Detection Sampling Four-wire sampling
Data Base Using SQL database to manage test data
Upper computer communication mode Based on TCP/IP Protocol/Serial Port
Data Output Mode EXCEL/TXT/Chart
Communication Interface Mesh port
Chassis dimensions 300x450x170mm
Cabinet size 900x600x1900mm
Spatial Dimension of Discharge Battery 900x600x130mm